Preliminary Site Investigation for Parkland Off-Leash Dog Park in North-East Victoria

Parkland in north-east Victoria assessed for an off-leash dog park preliminary site investigation

iEnvi completed a preliminary site investigation of council-owned former railway parkland in north-east Victoria for a proposed off-leash dog park. Surface soils were below recreational criteria, and a simple construction environmental management plan was recommended.

Metropolitan Bus Depots – Environmental Compliance and Investigations

Practical environmental investigations and compliance audits across four Melbourne bus depots established a defensible baseline, identified localised hydrocarbon impacts near refuelling areas, confirmed no landfill‑gas risk from adjacent closed tips, and delivered reporting and management measures to meet Victorian regulatory expectations.

Landfill Gas Assessment, Bus Depot, Melbourne West

Landfill gas monitoring at an operating bus depot in Melbourne's western suburbs

Targeted landfill gas and groundwater assessment at an operating bus depot adjacent to two closed municipal landfills in Melbourne’s western suburbs. No methane detected and EPA Victoria action levels not exceeded. Planning condition satisfied with no further LFG controls recommended.

Baseline Environmental Condition Investigation – Western Melbourne Bus Depot

iEnvi completed a Baseline Environmental Condition Investigation (BECI) at an established western Melbourne bus depot to meet Department of Transport & Planning requirements. Targeted soil and groundwater testing (10 soil bores and monitoring wells) found no significant contamination; a Fuel System Operating Plan (FSOP) was recommended and reporting provided regulator‑defensible documentation under Victoria’s Environment Protection Act 2017.

Preliminary Site Investigation, Inner Melbourne Residential Development

Aerial view of an inner Melbourne residential development site assessed by iEnvi

iEnvi completed a desk-based Preliminary Site Investigation (PSI) for a proposed residential development in inner Melbourne, Victoria. The PSI found a low risk of contamination, confirmed intrusive soil testing was not required, and enabled the planning application to proceed without an environmental audit.

Soil Investigation Clears Path for Safe Construction at Chemical Site, Victoria

iEnvi completed an asbestos- and contaminant-focused soil classification at an industrial chemical site in Melbourne, providing a compliant, cost-effective pathway for excavation and construction of a flammable goods storage area.

Compliance Investigation and Cost‑Effective Remediation of Asbestos‑Impacted Soil at a Northern Melbourne Industrial Site (VIC)

industrial site land

iEnvi investigated asbestos‑impacted soil and groundwater at an industrial site in northern Melbourne (VIC). Bonded asbestos in stockpiled soil was removed by hand‑picking (emu‑picking) and the remaining material verified for reuse as clean fill, avoiding costly landfill disposal while meeting EPA Victoria obligations under the General Environmental Duty.